BHA-5100 Automatic Blood Cell Analyzer Medical Equipment for Hospitals

Brand Name: Getein
Methodology: Electrical Impedance Method and Colorimetry
Certificate: CE, Nmpa
Sample Type: Whole Blood (Venous/Capillary Blood), Pre-Dilution
Application: Hospital, Clinic, Laboratory
Dimension: 328mm*425mm*466mm
Customization:

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Test Principles
  • Certifications
  • Company Profile
  • EXHIBITIONS
  • FAQ
Overview

Basic Info.

Model NO.
BHA-5100
Weight
21 Kg
Power Supply
100-240 V~50/60 Hz
Data Storage
10,000
Screen Type
10.4 Inch Resistive Screen
Transport Package
Air Freight/ Ship Freight /Train
Specification
328 mm*471 mm*446 mm (L*W*H)
Trademark
getein
Origin
China
Production Capacity
5000000

Product Description

Product Description

BHA-5100 Automatic Hematology Analyzer

At Getein, we are committed to listening to the needs of each client and providing tailor-made solutions. In today's clinical world, it seems that a single instrument is no longer sufficient to meet the growing demand for testing, so the Modular System, which combines multiple testing instruments into one, has been created. The Getein BHA-5100, available in the Metis 600 Modular System, meets all these clinical requirements and exceeds your expectations!

Detailed Photos

BHA-5100 Automatic Blood Cell Analyzer Medical Equipment for Hospitals

Product Parameters
Type
Blood Analysis SYstem
Brand Name
Getein
Product name
BHA-5100 Automatic Hematology Analyzer
Methodology
Laser Scattering + Sheath Flow Technology
Dimensions
67 cm x 70.5 cm x 57 cm
Weight
21 kg
Sample Mode
Whole Blood (Venous/Capillary) Pre-dilution
Reagents
1 Diluent and 2 Lyses
QC Methods
L-J QC, X-B QC
Screen Type
10.4 Inch Resistive Screen
Data Storage
100000
Power Supply
100-240 V~ 50/60 Hz
25 Reportable Parameters
WBC,Lym#,Neu#,Mon#,Eos#,Bas#, Lym%,Mon%,Neu%,Eos%,Bas%,RBC,HGB, HCT,MCV,MCH,MCHC,RDW-SD,RDW-CV,PLT,MPV,PDW,PCT,P-LCR,P-LCC
Principles
White Blood Cell: Laser Scattering+ Sheath Flow Technology
Red Blood Cell/Platelet: Impedance Method
Hemoglobin: Photoelectric Colorimetry
Sample Volume
Venous blood: 15 μL
Capillary blood (Pre-dilution): 20 μL
Operating Conditions
18~30°C, <80% Relative Humidity, 
75 kPa~106 kPa
Features:

* Large Display Screen

≥10.4 inch LCD display screen
Able to display data and diagrams simultaneously
 
* Automatic Puncture Sampling
Avoid aerosol. Ensure biosafety
 
 
* Floating Threshold Technology
Autorotating blood collection tube
Mechanized standard sampling system

* Automatic Sample Mixing Technology

Eliminate error caused by manual mixing
 
 
* Smallest Gem Hole
Industry's smallest 50 µm diameter for unparalleled sensitivity
 
* Detection Technology
Laser Scattering + Sheath Flow Technology

Specification:

External laser printer connectivity
External keyboard and mouse connectivity
Bidirectional connectivity of LIS and HIS
Emergency sample position available
Storage capacity: > 100,000 patient data
Patient data can be searched, deleted, and printed out
Closed testing system ensuring biosafety
Test Principles

BHA-5100 Automatic Blood Cell Analyzer Medical Equipment for Hospitals

Certifications
BHA-5100 Automatic Blood Cell Analyzer Medical Equipment for Hospitals
BHA-5100 Automatic Blood Cell Analyzer Medical Equipment for Hospitals
BHA-5100 Automatic Blood Cell Analyzer Medical Equipment for Hospitals

 

Company Profile

BHA-5100 Automatic Blood Cell Analyzer Medical Equipment for HospitalsGetein Biotech, Inc(stockcode:603387), established in 2002, is a fully integrated into vitro diagnostic company that researches and develops manufactures, markets, and distributes a broad range of innovative diagnostic test kits in point-of-care testing(POCT).In July 2017Getein Biotech got listed on the main board of the Shanghai Stock Exchange.
With the great contribution of our advanced R&D center and 19-year continuous developmentGetein Biotech has developed 8 technology platforms including Point-of-Care Testing(POCT), clinical chemistry, and chemicals
luminescence. hematology coagulation urinalysis. molecular diagnostics and raw materials for diagnostic reagents, covering fields of cardiovascular disease kidney injury diabetes mellitus gestation infectious disease cancer, etc.

EXHIBITIONS
 
BHA-5100 Automatic Blood Cell Analyzer Medical Equipment for Hospitals
BHA-5100 Automatic Blood Cell Analyzer Medical Equipment for Hospitals
BHA-5100 Automatic Blood Cell Analyzer Medical Equipment for Hospitals

 

FAQ

 

1. Q: Are you a trading company or manufacturer?
A: We are a manufacturer established in 2002.

2. Q: what can you buy from us?
A: IVD products, POCT equipment and reagents, Hematology equipment and reagents, chemiluminescence equipment and reagents, biochemistry equipment, etc.

3. Q: Do you provide samples? Is it free or extra?
A: Yes, if you buy equipment we could offer a sample test for free charge but do not pay the cost of freight.

4. Q: What are your terms of payment?
A: 100% T/T in advance

5. Q: What is your warranty?
A: For most products the warranty is for 12 months, for some products we provide 18 months warranty.

6. How to ship the product?
A: The shipping way normally depends on your quantity, total CBM, and weight.
We have our own shipping company to provide the best shipping cost and the most efficient way.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Year of Establishment
2002-03-08
Plant Area
83000 square meters